EXIM SMART METER UNTUK SOFT-INTEGRATED MAINGRID DAN MICROGRID BERBASIS ESP8266

Jannah, Niswatul and Dewantara, Ilham Miranda and Arifandi, Arya and Efendi, Iwan (2024) EXIM SMART METER UNTUK SOFT-INTEGRATED MAINGRID DAN MICROGRID BERBASIS ESP8266. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (1MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (429kB) | Preview
[thumbnail of BAB II.pdf]
Preview
Text
BAB II.pdf

Download (419kB) | Preview
[thumbnail of BAB III.pdf]
Preview
Text
BAB III.pdf

Download (612kB) | Preview
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (615kB) | Request a copy
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (791kB) | Request a copy
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
[thumbnail of POSTER.pdf] Text
POSTER.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Exim smart meter is an electrical energy metering device designed to monitor and manage energy consumption in real-time. The ever-increasing demand for energy encourages the utilisation of renewable energy sources. One of the problems faced is how to effectively integrate renewable energy with the PLN main power grid (maingrid). Exim smart meter is a solution in overcoming integrating energy from 2 sources of microgrid and maingrid and this tool can monitor energy consumption from maingrid and energy production from microgrid in realtime using IoT technology based on ESP8266 with the help of PZEM004T sensors that can measure electrical parameters. The methods used are Kirchoff's law and logic gates to analyse and manage the flow of current and voltage in the system. The test results with the load of the lamp used power of 8.4 watts, on the load of the electric pot of 488.5 watts and hairdryer of 600.4 watts and can be exported from microgrid to maingrid of 2188.739 watts when using hairdryer load. From the tests that have been carried out, it can be concluded that Exim smart meters not only help control daily energy use but also can reduce the cost of spending PLN electricity bills and can integrate from 2 sources both maingrid and microgrid.

Item Type: Thesis (Undergraduate)
Student ID: 202010130311075 201810130311049 202010130311061 201810130311222
Keywords: Exim smart meter,IoT, maingrid, microgrid, ESP8266
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering