STUDI PERENCANAAN SISTEM PLAMBING DAN SISTEM PEMADAM KEBAKARAN PADA GEDUNG RUMAH SAKIT GRESIK SEHATI

Nusyaibah, Iffah (2024) STUDI PERENCANAAN SISTEM PLAMBING DAN SISTEM PEMADAM KEBAKARAN PADA GEDUNG RUMAH SAKIT GRESIK SEHATI. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (2MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (567kB) | Preview
[thumbnail of BAB II.pdf]
Preview
Text
BAB II.pdf

Download (1MB) | Preview
[thumbnail of BAB III.pdf]
Preview
Text
BAB III.pdf

Download (706kB) | Preview
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (3MB) | Request a copy
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (527kB) | Request a copy
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (5MB) | Request a copy

Abstract

This research is motivated by the availability of clean water needs and the amount of wastewater in the construction of the Gresik Sehati Hospital Building. In a building, it is necessary to have a clean water system and wastewater system or commonly called a plumbing system and a fire extinguishing system to prevent the risk of fire in the building. In planning the plumbing system for the Gresik Sehati Hospital Building, data on the required clean water discharge, water tank capacity, design of the pipe clean water and waterwaste systems, and the planning of hydrant system in the building are required. The planning are as follows the clean water requirement flow rate for the Gresik Sehati Hospital is 15.16 m3/hour or 4.21 liter/second, the capacity of the Ground Water Tank for clean water is 48 m3, the capacity of the Ground Water Tank for Hydrant is 150 m3, the capacity of the Roof Tank is 32 m3 and the capacity of the Sewage Treatment Plan is 28 m3. The planned sewage and wastewater disposal system in the Gresik Sehati Hospital is a separate system where the sewage and wastewater are discharged thorough different pipes using PVC pipes. The hydrant system in this hospital uses 3 indoor hydrant boxes/fire hose reek and 4 portable fire extinguisher on each floor and 2 outdoor pillar hydrant.

Item Type: Thesis (Undergraduate)
Student ID: 201910340311195
Keywords: Clean Water, Waste Water, Plumbing, Hydrant Systems, Water Storage
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TC Hydraulic engineering. Ocean engineering
Divisions: Faculty of Engineering > Department of Civil Engineering (22201)
Depositing User: 201910340311195 iffahnusyaibah07
Date Deposited: 12 Aug 2024 01:33
Last Modified: 12 Aug 2024 01:33
URI: https://eprints.umm.ac.id/id/eprint/9851

Actions (login required)

View Item
View Item