PERENCANAAN STRUKTUR BAWAH PADA GEDUNG KANTOR WILAYAH BANK RAKYAT INDONESIA KOTA MALANG MENGGUNAKAN PONDASI TIANG PANCANG

Sari, Dian Fadhilah (2024) PERENCANAAN STRUKTUR BAWAH PADA GEDUNG KANTOR WILAYAH BANK RAKYAT INDONESIA KOTA MALANG MENGGUNAKAN PONDASI TIANG PANCANG. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (3MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (501kB) | Preview
[thumbnail of BAB II.pdf]
Preview
Text
BAB II.pdf

Download (2MB) | Preview
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (6MB) | Request a copy
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (336kB) | Request a copy
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Malang City is one of the cities in East Java which has a fairly dense population. This can lead to community demands in the fulfillment of living facilities and infrastructure, one of which is the construction of buildings for community services such as bank offices. Bank Rakyat Indonesia Regional Office Building is one of the branch offices located on Jalan Laksamana Martadinata No.80 which has a height of 46.4 m consisting of 11 floors, including 8 main floors along with 1 roof floor, and 2 basement floors as parking lots. Based on the structural analysis of the supporting application STAADPro V22, the largest axial force at the foot of column K-10 is 18400 KN. A spun pile with a diameter of 0.6 m is planned, with a bearing capacity of 2256.37 kN for a depth of 12.2m from the basement floor. Pile cap is planned for 4 types, where in the existing condition the largest type is type 1 with pile cap dimensions of 5.4 m x 8 m x 1.2 m with D28-75 mm main reinforcement, while shrinkage reinforcement uses ∅19-150 mm. The length of filler concrete is planned at 950 mm with 14-D19 longitudinal reinforcement and ∅10-60 mm spiral reinforcement. The largest settlement occurred in pile cap type 1 of 0.8 cm.

Item Type: Thesis (Undergraduate)
Student ID: 201710340311032
Keywords: Pile Foundation, Soil bearing capacity, Pile cap, Reinforcement, Settlement.
Subjects: Q Science > Q Science (General)
Q Science > QA Mathematics
Q Science > QC Physics
Q Science > QE Geology
Divisions: Faculty of Engineering > Department of Civil Engineering (22201)
Depositing User: 201710340311032 dianfadhilah
Date Deposited: 09 Aug 2024 06:28
Last Modified: 09 Aug 2024 06:28