KEANDALAN SISTEM DISTRIBUSI TENAGA LISTRIK 20 KV TIPE AAAC, AAAC-S PADA PENGHANTAR SALURAN UDARA TEGANGAN MENENGAH PT.PLN (Persero) AREA BANYUWANGI-GAMBIRAN

Hermawan, Andiko Dwiky (2024) KEANDALAN SISTEM DISTRIBUSI TENAGA LISTRIK 20 KV TIPE AAAC, AAAC-S PADA PENGHANTAR SALURAN UDARA TEGANGAN MENENGAH PT.PLN (Persero) AREA BANYUWANGI-GAMBIRAN. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (2MB) | Preview
[thumbnail of BAB I fix.pdf]
Preview
Text
BAB I fix.pdf

Download (74kB) | Preview
[thumbnail of BAB II fix.pdf]
Preview
Text
BAB II fix.pdf

Download (570kB) | Preview
[thumbnail of BAB III fix.pdf] Text
BAB III fix.pdf
Restricted to Registered users only

Download (274kB) | Request a copy
[thumbnail of BAB IV fix.pdf] Text
BAB IV fix.pdf
Restricted to Registered users only

Download (450kB) | Request a copy
[thumbnail of BAB V fix.pdf] Text
BAB V fix.pdf
Restricted to Registered users only

Download (64kB) | Request a copy
[thumbnail of Poster Andiko Dwiky Hermawan_201810130311228.pdf]
Preview
Text
Poster Andiko Dwiky Hermawan_201810130311228.pdf

Download (385kB) | Preview

Abstract

The distribution network is the final stage of the channel that distributes electricity from the transmission network to the load. To get the most efficient distribution of electricity, it is necessary to choose the most appropriate type of conductor, which is in accordance with the load it will deliver. The distribution network is the part of the electric power system that is closest to the customer and the most disturbed. One major problem in distribution system operation is overcoming disturbances. In this research study, it is carried out to calculate the feasibility characteristics of the Gambiran transmission line using the AAAC and AAAC-S conductor types and calculate the reliability of the distribution system using the SAIDI and SAIFI methods. From the results of the feasibility test of the type of cross section with ETAP software, it is found that the AAAC-S cable has a lower loss of 70.53 when compared to the

Item Type: Thesis (Undergraduate)
Student ID: 201810130311228
Keywords: Keywords: Reliability, distribution system, SAIDI, SAIFI
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering