PERENCANAAN SISTEM PLUMBING AIR BERSIH DAN AIR LIMBAH PADA PEMBANGUNAN GEDUNG PAVILLIUN RUMAH SAKIT DR. SAIFUL ANWAR KOTA MALANG

Rumagutawan, Erna Restiana (2024) PERENCANAAN SISTEM PLUMBING AIR BERSIH DAN AIR LIMBAH PADA PEMBANGUNAN GEDUNG PAVILLIUN RUMAH SAKIT DR. SAIFUL ANWAR KOTA MALANG. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (2MB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (785kB) | Preview
[thumbnail of BAB II.pdf]
Preview
Text
BAB II.pdf

Download (2MB) | Preview
[thumbnail of BAB III.pdf]
Preview
Text
BAB III.pdf

Download (904kB) | Preview
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (3MB) | Request a copy
[thumbnail of BAB V .pdf] Text
BAB V .pdf
Restricted to Registered users only

Download (699kB) | Request a copy
[thumbnail of LAMPIRAN.pdf] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

Hospital are facilities that provide services that can lead to environmental pollution and health issues. One effort to prevent this is the need for good sanitation in hospitals. This planning aims to determine the need for clean water and wastewater generated at the Pavilion Building of dr. Saiful Anwar Hospital. The method used in this planning is to compare the number of occupants, types and quantities of plumbing fixtures. To meet the need for clean water in the Pavilion Building of dr. Saiful Anwar Hospital, 136.8 m3/day of clean water is required, and the amount of wastewater generated is 109.44 m3/day. The capacity of the Ground Water Tank is 48 m3, and the Rooftank is 25 m3. Based on the calculation results, a transfer pump is used to flow water from the Ground Water Tank to the Rooftank with a flow capacity of 16.2 m3/hour. The pump used is the 3 kW CP 210B 4 HP 3 Phase Centrifugal Pump. The drainage system used is a separate system, where dirty water is first collected in a septic tank, while wastewater and medical waste go to the Wastewater Treatment Plant (IPAL), which will then be treated with an Aerobic-Anaerobic Biofilter process to ensure it is safe when discharged into public drains.

Item Type: Thesis (Undergraduate)
Student ID: 201810340311165
Keywords: Plumbing, Hospital, Clean Water, Wastewater
Subjects: T Technology > TC Hydraulic engineering. Ocean engineering
Divisions: Faculty of Engineering > Department of Civil Engineering (22201)