PERENCANAAN SAMARA RESORT KOTA BATU MENGGUNAKAN STRUKTUR BAJA DENGAN METODE LOAD RESISTANCE FACTOR DESIGN

Firmansyah, Fani (2026) PERENCANAAN SAMARA RESORT KOTA BATU MENGGUNAKAN STRUKTUR BAJA DENGAN METODE LOAD RESISTANCE FACTOR DESIGN. Undergraduate thesis, Universitas Muhammadiyah Malang.

[thumbnail of PENDAHULUAN.pdf]
Preview
Text
PENDAHULUAN.pdf

Download (891kB) | Preview
[thumbnail of BAB 1 .pdf]
Preview
Text
BAB 1 .pdf

Download (576kB) | Preview
[thumbnail of BAB 2 .pdf]
Preview
Text
BAB 2 .pdf

Download (3MB) | Preview
[thumbnail of BAB 3.pdf] Text
BAB 3.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[thumbnail of BAB 4.pdf] Text
BAB 4.pdf
Restricted to Registered users only

Download (7MB) | Request a copy
[thumbnail of BAB 5.pdf] Text
BAB 5.pdf
Restricted to Registered users only

Download (621kB) | Request a copy

Abstract

Samara Resort Hotel in Batu City currently uses a reinforced concrete structure, which has limitations in resisting tensile forces and requires a longer construction time. This study proposes an alternative design by utilizing a composite steel structure that offers advantages in tensile strength, lighter weight, and greater efficiency in resisting loads.

The redesign of Samara Resort Batu City employs a composite steel structure using the Load and Resistance Factor Design (LRFD) method. The design refers to SNI 1727:2020 concerning Minimum Loads for the Design of Buildings and Other Structures, SNI 1729:2020 concerning Specification for Structural Steel Buildings, SNI 1726:2019 concerning Seismic Design Procedures for Buildings and Non-Building Structures, SNI 7972:2020 concerning Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, SNI 7860:2020 concerning Seismic Provisions for Structural Steel Buildings, and ANSI/AISC 360-2016: Specification for Structural Steel Buildings.

Based on the results of the structural analysis and design calculations, it can be concluded that the building utilizes a composite floor slab with a thickness of 120 mm, a base metal thickness of 0.70 mm, and W-1000 type floordeck manufactured by PT. Union Metal. The steel profiles used for beams, columns, and bracing are as follows: secondary beams in the Z direction use WF 250×125×6×9 sections; primary beams in the Z direction use WF 600×300×12×25 sections; primary beams in the X direction use WF 600×300×12×25 sections; columns use WF 600×600×15×30 sections; and bracing members use WF 200×200×8×12 sections

Item Type: Thesis (Undergraduate)
Student ID: 201910340311218
Keywords: Composite Steel Structure, LRFD, Special Concentric Bracing
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: Faculty of Engineering > Department of Civil Engineering (22201)
Depositing User: 201910340311218 fanifirmansyah
Date Deposited: 09 Feb 2026 04:45
Last Modified: 09 Feb 2026 04:45
URI: https://eprints.umm.ac.id/id/eprint/27406