UMM Institutional Repository

ANALISA ALIRAN DAYA PADA JARINGAN ARSITEKTUR CENTRALIZED GENERATION AND CENTRALIZED STORAGE (CGCS) DC MICROGRID MENGGUNAKAN METODE BACKWARD FORWARD SWEEP (BFS)

Al Karim, Disca (2022) ANALISA ALIRAN DAYA PADA JARINGAN ARSITEKTUR CENTRALIZED GENERATION AND CENTRALIZED STORAGE (CGCS) DC MICROGRID MENGGUNAKAN METODE BACKWARD FORWARD SWEEP (BFS). Undergraduate (S1) thesis, Universitas Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (1MB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (405kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (722kB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (832kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (237kB) | Request a copy
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (479kB) | Request a copy
[img]
Preview
Text
POSTER.pdf

Download (516kB) | Preview

Abstract

One solution to overcome the electrification problem in rural areas is to build a DC microgrid. This study discusses the architectural design of the Centralized Generation and Centralized Storage (CGCS) DC microgrid and the analysis of its power flow. This architectural design is limited to the use of a radial interconnection system with solar panels and batteries as sources and connected to three loads. Simulation using Simulink and obtained high-efficiency results of 99.982% when the load is set to a minimum. However, when the load is set to maximum, the efficiency decreases to 89.236% accompanied by lower voltage drop and higher line loss. This study also discusses the analysis of power flow in the CGCS DC microgrid distribution system architecture. The Backward Forward Sweep (BFS) method is used in the distribution system calculation analysis process because it is considered the most suitable for completing the radial distribution system calculation analysis. As a result, with a line length setting of 15 meters, the highest efficiency is 99.8157%. However, when the length of the channel is enlarged, the efficiency decreases because of line losses.

Item Type: Thesis (Undergraduate (S1))
Student ID: 201710130311099
Thesis Advisors: Machmud Effendy (0715067402), Ilham Pakaya (0717018801)
Keywords: DC Microgrid, Centralized Generation Centralized Storage, Radial Interconnection, Load Flow Analysis, Backward Forward Sweep.
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering > Department of Electrical Engineering (20201)
Depositing User: 201710130311099 discaalkarim
Date Deposited: 26 Mar 2022 01:36
Last Modified: 26 Mar 2022 01:36
URI : http://eprints.umm.ac.id/id/eprint/86056

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : repository@umm.ac.id - Website : https://lib.umm.ac.id - Online Catalog : https://laser.umm.ac.id - Repository : https://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo