Hidayatullah, Roni (2021) STUDI PERENCANAAN STRUKTUR RESERVOIR DENGAN MENGUNAKAN BETON BERTULANG PROYEK SPAM PEMANDIAN ALAM BANYUBIRU KAB. PASURUAN. Undergraduate (S1) thesis, Universitas Muhammadiyah Malang.
|
Text
PENDAHULUAN.pdf Download (2MB) | Preview |
|
|
Text
BAB I.pdf Download (344kB) | Preview |
|
|
Text
BAB II.pdf Download (804kB) | Preview |
|
|
Text
BAB III.pdf Download (854kB) | Preview |
|
![]() |
Text
BAB IV.pdf Restricted to Registered users only Download (2MB) | Request a copy |
|
![]() |
Text
BAB V.pdf Restricted to Registered users only Download (663kB) | Request a copy |
|
![]() |
Text
LAMPRAN.pdf Restricted to Registered users only Download (3MB) | Request a copy |
Abstract
The ground water tank reservoir is a structural building that function as a reservoir for water from intake spring, wich will be pumped and processed for the daily needs of human life and living things in the universe. With the ground water tank structure, the water flow can be controlled and can be used as a place for sedimantation to settle. This final project plans a ground water tank reservoir structure using reinforced concrete material, ground water tank with a length of 17.00m and a width of 10.50m with a building height of 6.05m, is at an elevation of -6.05m belom ground level. Based on the results of analysis, the dimensions of the roof plate are 120mm thick and the main reinforcement is Ø10 – 175mm, wall plate with a thickness of 200 mm and main reinforcement D13 – 175mm, bottom plate with a thickness of 120 mm and main reinforcement D16 – 250mm. Roof joist beam with dimension 15/20 using main support and field reinforcement 2 Ø 10 and using stirrup 10 Ø 100, roof main beam with dimension 25/35 using staple reinforcement 3 D 13 and field 2 D 13 and using stirrup reinforcement 10 Ø 100, X direction wall plate beam with dimension 35/50 using staple reinforcement 5 D 13 and field 4 D 13 using stirrup reinforcement 10 Ø 100, tie beam joists with dimension 15/20 using staple reinforcement and field 2 Ø 10 using stirrup reinforcement 10 Ø 100, tie main beam with dimension 25/35 using staple reinforcement 3 D 13 and field 2 D 13 and using stirrup reinforcement 10 Ø 100
Item Type: | Thesis (Undergraduate (S1)) |
---|---|
Student ID: | 201410340311244 |
Thesis Advisors: | Ernawan Setyono (0726016702), Yunan Rusdianto (0728065901) |
Keywords: | Ground Water Tank, Reinforced Concrete, Bellow Ground Level |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TC Hydraulic engineering. Ocean engineering T Technology > TH Building construction |