PERENCANAAN STRUKTUR GEDUNG TAHAN GEMPA MENGGUNAKAN METODE SISTEM GANDA YANG MENGACU PADA SNI – 1726 – 2012 PADA HOTEL GRAND SENGKALING UMM INN

Anwar, Zaivul (2018) PERENCANAAN STRUKTUR GEDUNG TAHAN GEMPA MENGGUNAKAN METODE SISTEM GANDA YANG MENGACU PADA SNI – 1726 – 2012 PADA HOTEL GRAND SENGKALING UMM INN. Undergraduate (S1) thesis, University of Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (865kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (170kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (2MB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (653kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (4MB)
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (215kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

The UMM INN hotel building uses an ordinary concrete structure or can be called SRPMK (Special Moment Resisting Frame System) by only using the system so that the dimensions of the beam column become larger. Therefore, it must be equipped with shear walls, the combination between shear walls and SRPMK is a popular choice because it is effective in providing security against earthquake conditions, or more so called MULTIPLE SYSTEM, is a structure suitable for category II because at least 25% will be detained by the portal and the rest will be held by the shear wall and make the planning of the structure more economical. From the re-planning of the structure the dimensions of the floor plate thickness were 12 cm, the thickness of the roof plate was 10 cm, the dimensions of the beam were 25/50 cm, the beam was 35/70 cm, the beam was 25/50 cm, the column 70/70 cm, and 30 cm thick shear wall. Reinforcement requirements required by the structure from the analysis and calculation are obtained Ø12 floor plate, Ø10 roof plate, transverse beam D16 with sengkang Ø10, main beam extending D25 with Ø12 sengkang, transverse beam D25 with Ø12 crossing, column D25 with stirrup and restraint D13, and shear walls with vertical reinforcement D16 and horizontal D13. The cross-sectional capacity of the structure is in accordance with the condition that ØMn ≥ Mu; ØVn ≥ Vu; ØPn ≥ Pu.

Item Type: Thesis (Undergraduate (S1))
Student ID: 201410340311031
Keywords: Earthquake, Shear Wall, Double System, High Building
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Engineering > Department of Civil Engineering (22201)
Depositing User: Retno Widiyastuti Ika Wijaya
Date Deposited: 28 Jun 2019 02:38
Last Modified: 10 Jul 2019 02:02
URI : http://eprints.umm.ac.id/id/eprint/46688

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : infopus[at]umm.ac.id - Website : http://lib.umm.ac.id - Online Catalog : http://laser.umm.ac.id - Repository : http://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo