UMM Institutional Repository

DESAIN ELECTRONIC LOAD CONTROLLER (ELC) PADA PLTMH MENGGUNAKAN BIDIRECTIONAL CONVERTER BERBASIS PID CONTROLLER

Rachman, Rofiqur (2019) DESAIN ELECTRONIC LOAD CONTROLLER (ELC) PADA PLTMH MENGGUNAKAN BIDIRECTIONAL CONVERTER BERBASIS PID CONTROLLER. Bachelors Degree (S1) thesis, University of Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (1MB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (235kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (751kB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (630kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (3MB)
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (126kB)

Abstract

Micro-Hydro Power Plant (MHPP) had problems in stabilizing the frequency and voltage. This problem could be overcome by using a system of Hydraulic Turbine and Governor (HTG) and a system of Electronic Load Controller (ELC). HTG served as the control of discharge of water that goes into the penstock could control the rotation of the turbine. ELC was used to maintain the stability of the voltage and frequency stabilizing in the ideal State by way of disposing of more power generated generator to the ballast load. ECL could absorb not only power but also could supply or also referred to as ELC using bidirectional converter. ELC used a bidirectional converter has a very good frequency response when there is a change of the load power. ELC it just takes 1 second to stabilize frequencies at 50 Hz again. ELC used a bidirectional converter using PID and DC chooper as control disposal power to the ballast load. ELC uses DC chooper as the switch to set the power to the ballast load so that ELC could be the inverter and 3 phase MOSFET series using as a main switch that is controlled by PID to control 2 converter properties i.e. rectifier and inverter. However, the system raised a large distortion ELC and exceeding standard of IEEE 519-1992. To resolve the problem that ELC used a bidirectional converter combined with the HTG at synchronous generator using the test and get the results a good frequency response and distortion managed to lose under the provisions of the standard IEEE 519-1992.

Item Type: Thesis (Bachelors Degree (S1))
Student ID: 201310130311096
Keywords: Micro Hydro power plants, Hydraulic turbine and governor, Electronic Load Controller, synchronous Generator.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering > Department of Electrical Engineering (20201)
Depositing User: CKO Repository
Date Deposited: 12 Mar 2019 01:17
Last Modified: 12 Mar 2019 01:17
URI : http://eprints.umm.ac.id/id/eprint/45095

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : infopus[at]umm.ac.id - Website : http://lib.umm.ac.id - Online Catalog : http://laser.umm.ac.id - Repository : http://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo