UMM Institutional Repository

ANALISIS KEBUTUHAN KAPASITOR BANK PADA BUS BEBAN UNTUK PERBAIKAN FAKTOR DAYA DAN DROP TEGANGAN MENGGUNAKAN SIMULASI OPTIMAL CAPACITOR PLACEMENT ETAP 12.6 (Studi kasus Bandar Udara Internasional Juanda Surabaya)

Anugrah, Haren Puja (2019) ANALISIS KEBUTUHAN KAPASITOR BANK PADA BUS BEBAN UNTUK PERBAIKAN FAKTOR DAYA DAN DROP TEGANGAN MENGGUNAKAN SIMULASI OPTIMAL CAPACITOR PLACEMENT ETAP 12.6 (Studi kasus Bandar Udara Internasional Juanda Surabaya). Bachelors Degree (S1) thesis, University of Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (590kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (170kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (551kB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (335kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (699kB)
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (176kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (520kB)

Abstract

In one airport terminal Juanda there are many load electricity having the character of inductive resulting in power factor of being inferior and occuring a decrease in voltage in the vicinity of the loads. Because of the very long of transmission line it can cause a voltage drop on the channel toward to load. The Optimal Capacitor Placement has a function to determine which bus that has a low power factor and voltage drop by placing a capacitor on the bus that has those problems. The bank capacitor has a function to improve the power factor and reduce the voltage drop on the channel. From ETAP 12.6 simulation results before the capacitor is placed the power factor on the central bus is 0,78 and the load bus has the lowest factor value 0,75. The voltage drop has occured in load busses with marginal categories have value in the average of 2,89% on bus 13,55,66 and 68. After the installing procces of capacitor the power factor on central bus is 0,95 and the load bus has the highest power factor of 0,99. The voltage drop after the capacitors installation on the critical load bus decline to 2,27% and on the buses with marginal category decline to the average value of 2,24%

Item Type: Thesis (Bachelors Degree (S1))
Student ID: 201410130311120
Keywords: Power Factor, Capacitor Bank, Optimal Capacitor Placement (OCP), Voltage Drop.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering > Department of Electrical Engineering (20201)
Depositing User: CKO Repository
Date Deposited: 25 Feb 2019 07:38
Last Modified: 25 Feb 2019 07:38
URI : http://eprints.umm.ac.id/id/eprint/44575

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : infopus[at]umm.ac.id - Website : http://lib.umm.ac.id - Online Catalog : http://laser.umm.ac.id - Repository : http://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo