UMM Institutional Repository

STUDI PERENCANAAN STRUKTUR ATAS GEDUNG A PASCA SARJANA UNIVERSITAS LAMBUNG MANGKURAT (UNLAM) MENGGGUNAKAN SISTEM FLAT SLAB

Fahreza, Muhammad Rian (2018) STUDI PERENCANAAN STRUKTUR ATAS GEDUNG A PASCA SARJANA UNIVERSITAS LAMBUNG MANGKURAT (UNLAM) MENGGGUNAKAN SISTEM FLAT SLAB. Bachelors Degree (S1) thesis, University of Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (211kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (44kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (951kB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (252kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (1MB)
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (88kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Flat slab is a relatively new system for our country because its application is still very little compared to the moment bearer frame system. The flat slab methods in Indonesia mostly used in malls that highlight the architectural side. In other high rise buildings such as offices, apartments, and hospitals, and many use the moment-bearing frame system rather than the flat slab method. In addition, peoples tend to choose the moment bearer frame system because it's considered to more solid and strong. The Building A post-graduate of Lambung Mangkurat University is located at Unlam Street, No. 12, Pangeran, Banjarmasin Utara, Banjarmasin, South Kalimantan, has a building size of 57.6 m x 31.2 m (1797.12 m). After the analysis and calculation, the data will be used in the process of structural planning, such as total plate of 22 cm, 10cm thick drop panel, and width of 2.4 m. Through on the STAAD application program. Pro V8i obtained the value of drift ratio in each direction of 0.0008, 0.0022, and 0.0022 which means the structure modeling in a stable state. Followed by plate reinforcement design using D16 and D22 column reinforcement

Item Type: Thesis (Bachelors Degree (S1))
Additional Information: 201210340311067
Uncontrolled Keywords: Flat slab, Drop panel, Two-way plate system
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Engineering > Department of Civil Engineering
Depositing User: Retno Widiyastuti Ika Wijaya
Date Deposited: 05 Jan 2019 01:28
Last Modified: 05 Jan 2019 01:28
URI : http://eprints.umm.ac.id/id/eprint/42916

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : infopus[at]umm.ac.id - Website : http://lib.umm.ac.id - Online Catalog : http://laser.umm.ac.id - Repository : http://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo