ANALISIS PERBAIKAN PROFIL TEGANGAN PADA JARINGAN DISTRIBUSI 20 KV MENGGUNAKAN KAPASITOR BANK DAN TAP TRANSFORMATOR (STUDI KASUS DI GI. SENGKALING)

Siregar, Rizki Awaluddin (2018) ANALISIS PERBAIKAN PROFIL TEGANGAN PADA JARINGAN DISTRIBUSI 20 KV MENGGUNAKAN KAPASITOR BANK DAN TAP TRANSFORMATOR (STUDI KASUS DI GI. SENGKALING). Bachelors Degree (S1) thesis, University of Muhammadiyah Malang.

[img]
Preview
Text
PENDAHULUAN.pdf

Download (846kB) | Preview
[img]
Preview
Text
BAB I.pdf

Download (183kB) | Preview
[img]
Preview
Text
BAB II.pdf

Download (903kB) | Preview
[img]
Preview
Text
BAB III.pdf

Download (198kB) | Preview
[img] Text
BAB IV.pdf
Restricted to Registered users only

Download (1MB)
[img] Text
BAB V.pdf
Restricted to Registered users only

Download (36kB)
[img] Text
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

A good electrical distribution system should have a voltage value that does not exceed the operational tolerance limits and small power losses. Evaluation of voltage stability needs to be done on an ongoing basis to obtain information on power distribution system performance. Calculation of power flow analysis is used to determine the important parameters of electrical systems in steady state. The voltage profile fixing can be done by using voltage regulation equipment, such as capacitor bank and tap transformator (trafo). Through the simulation using Matlab R2012b application will obtain the appropriate capacitor bank and tap transformator to improve the performance. From the simulation results conducted on Pujon repeater distribution system there are several substations that experience a total voltage drop of 12.7%. After the addition of capacitor bank, the voltage on the system has increased significantly and does not exceed the limit of voltage tolerance and voltage drop to 4.6% and power factor increases. For the adjustment of the tap transformator ratio, the voltage drop improvement is seen on the secondary side of the relay station tansformator arranged according to the voltage difference on the primary side. The results obtained after the application of capacitor bank and tap ttransformator is the value of voltage drop becomes reduced to 3.5%

Item Type: Thesis (Bachelors Degree (S1))
Additional Information: 201210130311145
Uncontrolled Keywords: Capasitor bank, Tap transformator, Voltage stability, Drop voltage, Power looses
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering > Department of Electrical Engineering
Depositing User: CKO Repository
Date Deposited: 29 Oct 2018 01:42
Last Modified: 29 Oct 2018 01:42
URI : http://eprints.umm.ac.id/id/eprint/38720

Actions (login required)

View Item View Item
UMM Official

© 2008 UMM Library. All Rights Reserved.
Jl. Raya Tlogomas No 246 Malang East Java Indonesia - Phone +62341464318 ext. 150, 151 - Fax +62341464101
E-Mail : infopus[at]umm.ac.id - Website : http://lib.umm.ac.id - Online Catalog : http://laser.umm.ac.id - Repository : http://eprints.umm.ac.id

Web Analytics

UMM Institutional Repository is powered by :
EPrints Logo